Call Us: +86-15967177856Email: [email protected]
enLanguage

What Cooling Methods Are Available For The Motor? Summary Of Common Motor Cooling Methods (Part 1)

Aug 14, 2021

During the use of the motor, due to the existence of loss, the temperature continues to rise. If it is not well cooled, the service life of the motor will be affected. Cooling is especially important for normal use.


For open-type motors, ambient air is generally used to directly enter the motor for cooling, and the cold air directly takes away the heat of the motor and discharges it to the surrounding environment. There are three main routes for the air to travel inside the high-voltage motor. One is axial, cold air enters from one end of the motor and exhausts from the other end. Because only one end of the fan is installed, a larger diameter fan can be installed, the cooling is better, and the iron core structure is more compact. The disadvantage is that the ventilation loss is large, and the temperature distribution along the axial direction of the motor is not uniform. It is generally used for motors with small capacity.


The other is radial, where cold air enters from both ends and is discharged from the radial air passages of the iron core. The disadvantage is that the fan must be installed at both ends, so the outer diameter of the fan can only be smaller than the diameter of the rotor. The fan capacity is limited and radial ventilation slots are required, making the motor slightly larger. The advantage is that due to the use of an axial flow fan, the ventilation efficiency is high, the heat dissipation area is large, and the temperature along the axial direction of the high-voltage motor is more uniform. There is also axial and radial composite ventilation, which is designed by combining the advantages of axial and radial ventilation. It has better ventilation and cooling, and the temperature is more uniform, but the structure is more complex.


Since the insulating material used in the motor has a temperature limit, the task of cooling the motor is to dissipate the heat generated by the internal loss of the motor, so that the temperature rise of each part of the motor is maintained within the range specified by the standard, and the internal temperature should be uniformized. .


The motor usually uses gas or liquid as the cooling medium, and the common ones are air and water, which we call air cooling or water cooling. Air cooling is commonly used for fully enclosed air cooling and open air cooling; water cooling is common with water jacket cooling and heat exchanger cooling.


The AC motor standard IEC60034-6 specifies and explains the cooling method of the motor, which is represented by the IC code: cooling method code = IC + circuit layout code + cooling medium code + driving method code